7. Troubleshooting

  • Control Box has No Power - Check and Verify power at terminal block using a multimeter. Remove two fuses and check and verify ampacity.
  • All Motors go in the wrong direction - Change Direction 1 and Direction 2 at the motor terminals on the premier remote control printed circuit board.
  • Some motors go in the wrong direction. Identify the motor(s) that are moving in the wrong direction. Option 1 (recommended) - Change the motor direction 1 and direction 2 at the motor terminals on the premier remote control printed circuit board. Option 2 - Change leads at motor by swapping wires identified with “*”. On “T” motors this is T5 and T8. On spade motors, this is typically motor red and motor black. Please see the wiring diagram in appendix B.
  • Front Panel is not responding or is not backlit - Refer to Section 3. Ensure the front panel ribbon is seated into the front panel terminal on the Printed Circuit Board.